Documentation review
Policies, Fire NOC conditions, drawings, approvals, maintenance records, training logs, drill reports, permits and previous observations.
Independent site review, evidence-based findings and prioritised action plans
Documentation review, physical inspection, fire-system evaluation, occupant-safety assessment, emergency-preparedness review and corrective-action reporting.
A fire safety audit is a structured review of fire hazards, prevention measures, installed protection systems, means of escape, emergency preparedness, maintenance records and compliance evidence at a facility.
Fire and safety audits evaluate how effectively a building or organisation prevents fire, detects and controls an incident, protects occupants and maintains readiness. The audit identifies observable hazards and gaps, compares available evidence with the agreed criteria and recommends corrective actions.
Reliance Fire Protection Systems supports fire audit enquiries from Mumbai for commercial, industrial, residential and infrastructure facilities across India.

Policies, Fire NOC conditions, drawings, approvals, maintenance records, training logs, drill reports, permits and previous observations.
Blocked exits, combustible storage, ignition sources, electrical hazards, housekeeping, emergency lighting, signage and access.
Visible condition and available records for detection, alarms, extinguishers, hydrants, pumps, sprinklers, suppression and communication systems.
Emergency plans, roles, evacuation procedures, assembly points, communication, training, drills and coordination arrangements.
Travel paths, exit capacity, accessibility, fire doors, compartmentation, stairways, refuge provisions and assembly management.
Applicable criteria, inspection evidence, testing frequency, identified gaps, responsibility tracking and closure documentation.
Control panels, detectors, call points, sounders, power supplies, fault status and interface records.
Selection, access, condition, inspection records, pumps, tanks, valves, hose reels and outlet coverage.
Valves, gauges, impairments, inspection records, cylinders, release controls, nozzles and room conditions.
Panels, cabling, temporary wiring, overload indicators, hot work, fuel systems, machinery and hazardous processes.
Escape routes, doors, stairs, signage, emergency lighting, smoke control and fire compartmentation.
Flammable materials, gas cylinders, chemicals, battery areas, waste, separation and emergency arrangements.
Factories, pharmaceutical plants, automotive facilities, chemical processes and engineering units.
Warehouses, cold storage, fulfilment centres, transport hubs and high-piled storage.
Data centres, IT parks, telecom sites, electrical rooms, control centres and airports.
Offices, malls, hotels, mixed-use buildings, cinemas and event spaces.
Hospitals, laboratories, schools, colleges and institutional campuses.
High-rise towers, housing societies, gated communities and redevelopment projects.
Fire safety audit enquiries are supported across all Indian states and union territories, subject to site access, agreed criteria and local requirements.
The existing coverage on this page includes enquiries from major industrial estates, SEZs, IT parks, logistics hubs and manufacturing clusters across India.
It is a structured review of hazards, prevention, installed protection systems, escape, emergency preparedness, records and compliance evidence.
The scope can include documents, hazards, exits, fire doors, extinguishers, hydrants, sprinklers, alarms, suppression, pumps, water storage and emergency plans.
Requirements vary by state, authority, occupancy, licence, Fire NOC conditions, insurer and company policy. The applicable requirements must be checked for each facility.
Factories, warehouses, offices, hospitals, hotels, malls, schools, data centres, residential buildings, logistics sites and infrastructure.
The report can include observations, photographs, risk rankings, gaps, system-condition findings and prioritised corrective actions.
No. A Fire NOC is issued only by the competent authority through its required submission and verification process.
Yes. We support audit enquiries across Indian states, union territories and major industrial zones.
Share the site location, occupancy, built-up area, processes, number of buildings, existing fire systems, Fire NOC status, preferred criteria and required reporting timeline.
Call +91 96999 90424 | sales@relifire.com | Contact Reliance Fire Protection Systems